| Home | Enrust | Biological | Other Products | MSDS | Photos | Contact Us |
Biological Options:
|
|
MICRO
-LIVE
|
![]() |
POWDERED BIOLOGICAL BACTERIA -- TRIPLE STRENGTH GREASE AND WASTE DIGESTER
Resistant to detergents, disinfectants, sanitizers, free chlorine and 200 degree F temperatures.
A POWERFUL WASTEWATER TREATMENT WEAPON
Users everywhere agree: This optimal blend of safe, live, non-toxic bacteria overcomes wastewater treatment problems in residential, commercial and municipal wastewater treatment systems.
COMPLETELY SAFE, EASY TO USE MICRO-LIVE ESTABLISHES IDEAL BACTERIAL POPULATIONS
MICRO-LIVE is a ready-to-use bio-enzymatic formulation (bacteria/enzyme blend) specifically designed to promote accelerated grease liquefaction and digestion. This unique bio-formulation combines patented specifically selected grease digesting bacteria with selected fat splitting crude enzymes to achieve the ultimate bio-formulation for difficult grease problems (grease traps, drains, lift stations, wet wells, and septic tanks.
MICRO-LIVE breaks and digests grease, fats, soap, scup, and other colloidals and dissolves organic materials in both anaerobic and aerobic wastewater treatment systems. In addition to dramatic improvements in oxidizing compounds, it promises major cost savings to users.
MICRO-LIVE keeps household systems operating properly for only pennies a day. The cost is even lower for larger systems. Field performance has proved that plant operating cost savings can be greater than the material cost for regular MICRO-LIVE treatments.
MICRO-LIVE provides even more benefits including lower operating costs, no dangerous chemicals to worry about, an end to noxious odors and sewage backups, lower effluent BOD and SS, quick recovery from shock loading, and reduced sludge production and reduced hydrogen sulfide generation in gravity flow systems.
MICRO-LIVE PROMISES TO LOWER OPERATING COSTS
By improving the oxidation of fats, oils, grease and detergents, MICRO-LIVE can reduce aeration capacity required. It can also reduce the need to use chemical settling aids (Polymers), cut energy costs, save defoamer expense, and lower overall labor costs.
MICRO-LIVE STOPS NOXIOUS ODORS
Because it can reestablish and enhance normal biological activity in wastewater treatment systems, MICRO-LIVE stops organic odors and prevents them from reoccurring as long as the maintenance program is followed.
MICRO-LIVE HELPS SYSTEMS MEET NATIONAL POLLUTION DISPOSAL ELIMINATION SYSTEMS (NPDES) PERMIT REQUIREMENTS
Laboratory tests prove that the MICRO-LIVE can reestablish and enhance biological activity and improve the reduction of BOD, COD, and SS in final effluent. Up to 80% more organic materials have been removed in some system through MICRO-LIVE treatments. It also helps maintain plant stability and provides rapid recovery from shock loading. Therefore, MICRO-LIVE helps systems meet National Pollution Disposal Elimination Systems permit requirements for BOD and SS in final effluent.
HOW MICRO-LIVE PREVENTS SEWAGE BACKUP AND REDUCES SLUDGE PRODUCTION
By enhancing biological activity in sewers, drain lines, treatment plants, septic tanks, and disposal fields and beds, MICRO-LIVE eliminates treat of sewage backup and reduces sludge deposits.
MICRO-LIVE is formulated to digest fats and grease to accelerate the decomposition process. Any clogging material in the leaching fields and beds is soon digested. (Efficient drainage can be restored quickly.) There is usually no need to replace problem fields and beds once they have been treated with MICRO-LIVE. Fats, oils, grease, detergents and other organic solids in septic tank are quickly digested by MICRO-LIVE. Clogging of disposal areas is minimized or eliminated.
The first MICRO-LIVE treatment begins to improve bacteria balance. Continued regular use soon establishes and maintained ideal bacteria populations.
MICRO-LIVE REDUCES ORGANIC LINE DEPOSITS MEANS LESS HYDROGEN SULFIDE
Lab tests and field performance analysis have revealed that MICRO-LIVE reduces hydrogen sulfide in gravity systems. Less hydrogen sulfide means an end to hydrogen sulfide odors as well, along with minimum line corrosion in gravity systems.
WHERE TO APPLY MICRO-LIVE
Municipal Systems Extended Aeration Package Plants Aerated and Non-Aerated Lagoons Collection Systems Conventional Activated Sludge Plants Aerobic and Anaerobic Sludge Digesters Contact Stabilization Plants Industrial Systems Lift Stations Polishing Ponds Trickling Filters Rotating Biological Contractors (RBCs) Imhoff Plants Septic Tanks Soil Absorption Fields and Sand Filters Grease Traps Down Pipes Cesspools Holding Tanks and Dump Stations Pit and Concrete Vault Toilets Composting Toilets Fish Hatcheries Recreational Ponds Agricultural Ponds and Manure Pits Stabilization Ponds
MICRO-LIVE
RECOMMENDED DOSAGE SCHEDULE
| AREA | Weekly Dosage | AREA | Weekly Dosage |
| Kitchen Drain |
2
oz.
|
Septic Tanks |
6
oz.
|
| Laundry drain |
2
oz.
|
Drain Fields |
6
oz.
|
| Bathroom Drain |
2
oz.
|
Lagoons |
1
lb./MGD
|
| Toilets |
2
oz.
|
Aerated Basins |
1-2
lbs./MGD
|
| Grease Traps |
2
oz.
|
Activated Sludge |
1-3
lbs./MGD
|
| Wet Wells |
2
oz.
|
Trickling Filters |
1
lb./MGD
|
| Lift Stations |
2
oz.
|
Digesters |
1
lb/7500GL
|
Waste Treatment Plants/Sludge Disposal Trucks: Please call our technical service department for additional product information. This product is available in bulk quantities.
Porta-Toilets: Add 2 oz. to tank.
Ponds, Lagoons: Use 1 lb. per gallons per million gallons of water flow/containment for 12 days. After initial treatment, use 1 lb. per million gallons of water per week.
HOW MICRO-LIVE WORKS FOR YOU
There usually arent enough natural bacteria in wastewater treatment systems to properly decompose the waste before it leaves the system. Manmade wastewater treatment systems suffer from high concentrations of organic waste, insufficient bacteria population and the absence of the right kind of bacteria to decompose organic waste. The results are noxious odors, sludge buildup, sewerage backups, wastes that are discharged before they are completely decomposed, facilities that are overloaded with organic waste, and a lot of expense for facility repair, disposal field or bed replacement and pollution clean-up.
MICRO-LIVE works like nature, introducing live, safe bacteria with known functions into your wastewater treatment facility to improve waste decomposition. These bacteria require specific nutrients in order to metabolize waste and reproduce. These food sources carbon, nitrogen, and phosphorus are found in abundance in the waste-waters in municipal treatment plants, septic tanks, extended aeration plants, package plants, lagoons and ponds, fish hatcheries, industrial plants, and all other treatment facilities.
Our selected bacteria are 100% biodegradable, non-toxic, non-pathogenic, and non-irritating. They are so safe, in fact, that the USDA approves them for use in meat, egg and poultry plants. Suspended in a dormant state, they live for more than 24 months inside our patented powdered solution. Once in contact with the nutrients present in your wastewater treatment facility, the bacteria are reactivated. This population goes to work to liquefy grease and fats, to reduce sludge buildup and line corrosion, to eliminate overloading and chemical shocks, to increase dissolved oxygen in the final effluent, and to dramatically reduce BOD, COD, and SS levels
MICRO-LIVE increases your wastewater treatment capacity, making it an obvious alternative to expansion of your facilities and a sensible was to extend the life of your facilities. Only small amounts are required, and its easy to apply from our containers. No pre-mixing devices are required. Apply according to instructions.
PACKED: 12-1 lb., 25 lbs., 50 lbs., and 100 lbs. Containers.
| |
MICRO
-ACTION |
![]() |
LIQUID BIOLOGICAL BACTERIA - TRIPLE STRENGTH GREASE AND WASTE DIGESTER
Resistant to detergents,
disinfectants, sanitizers, free chlorine, and 200-degree F temperatures.
Neutralizes odors, fresh clean scent, and biodegradable
A POWERFUL WASTEWATER TREATMENT WEAPON
Users everywhere agree:
This blend of safe, live, non-toxic bacteria overcomes wastewater treatment
Problems in residential, commercial and municipal wastewater treatment systems,
COMPLETELY SAFE, EASY TO USE MICRO-ACTION ESTABLISHES IDEAL BACTERIAL POPULATIONS
MICRO-ACTION
is a ready-to-use bio-enzymatic formulation (bacteria/enzyme blend) specifically
designed to promote accelerated grease liquefacation and digestion. This unique
bio-formulation combines patented specifically selected grease digesting bacteria
with selected fat splitting crude enzymes to achieve the ultimate bio-formulation
for difficult grease problems (grease traps, drains, lift stations, wet wells,
and septic tanks.
MICRO-ACTION breaks and digests grease,
fats, soap, scup, and other colloidals and dissolves organic materials in both
anaerobic and aerobic wastewater treatment systems. In addition to dramatic
improvements in oxidizing compounds, it promises major cost savings to users.
MICRO-ACTION keeps household systems operating
properly for only pennies a day. The cost is even lower for larger systems.
Field performance has proved that plant operating cost savings can be greater
than the material cost for regular MICRO-ACTION
treatments.
MICRO-ACTION provides even more benefits
including lower operating costs, no dangerous chemicals to worry about, an end
to noxious odors and sewage backups, lower effluent BOD and SS, quick recovery
from shock loading, and reduced sludge production and reduced hydrogen sulfide
generation in gravity flow systems.
MICRO-ACTION PROMISES TO LOWER OPERATING COSTS
By improving the oxidation of fats, oils, grease and detergents, MICRO-ACTION can reduce aeration capacity required. It can also reduce the need to use chemical settling aids (Polymers), cut energy costs, save defoamer expense, and lower overall labor costs.
STOPS NOXIOUS ODORS
Because it can reestablish and enhance normal biological activity in wastewater treatment systems, MICRO-ACTION stops organic odors and prevents them from reoccurring as long as the maintenance program is followed.
HELPS SYSTEMS MEET NATIONAL POLLUTION DISPOSAL ELIMINATION SYSTEMS (NPDES) PERMIT REQUIREMENTS
Laboratory tests prove that the MICRO-ACTION can reestablish and enhance biological activity and improve the reduction of BOD, COD, and SS in final effluent. Up to 80% more organic materials have been removed in some system through MICRO-ACTION treatments. It also helps maintain plant stability and provides rapid recovery from shock loading. Therefore, MICRO-ACTION helps systems meet National Pollution Disposal Elimination Systems permit requirements for BOD and SS in final effluent.
HOW MICRO-ACTION PREVENTS SEWAGE BACKUP AND REDUCES SLUDGE PRODUCTION
By enhancing biological
activity in sewers, drain lines, treatment plants, septic tanks, and disposal
fields and beds, MICRO-ACTION eliminates
treat of sewage backup and reduces sludge deposits.
MICRO-ACTION is formulated to digest fats
and grease to accelerate the decomposition process. Any clogging material in
the leaching fields and beds is soon digested. (Efficient drainage can be restored
quickly.) There is usually no need to replace problem fields and beds once they
have been treated with MICRO-ACTION.
Fats, oils, grease, detergents and other organic solids in septic tank are quickly
digested by MICRO-ACTION. Clogging of disposal
areas is minimized or eliminated.
The first MICRO-ACTION treatment begins
to improve bacteria balance. Continued regular use soon establishes and maintained
ideal bacteria populations.
REDUCED ORGANIC LINE DEPOSITS MEANS LESS HYDROGEN SULFIDE
Lab tests and field performance analysis have revealed that MICRO-ACTION reduces hydrogen sulfide in gravity systems. Less hydrogen sulfide means an end to hydrogen sulfide odors as well, along with minimum line corrosion in gravity systems.
WHERE TO APPLY MICRO-ACTION
Municipal Systems Extended Aeration Plants Package Plants Aerated and Non-Aerated Lagoons Collection Systems Septic Tanks Conventional Activated Sludge Plants Aerobic and Anaerobic Sludge Digesters Contact Stabilization Plants Industrial Systems Lift Stations Polishing Ponds Trickling Filters Rotating Biological Contractors (RBC's) Imhoff Plants Soil Absorption Fields and Sand Filters Grease Traps Down Pipes Cesspools Holding Tanks and Dump Stations Pit and Concrete Vault Toilets Composting Toilets Fish Hatcheries Recreational Ponds Agricultural Ponds and Manure Pits Stabilization Ponds
MICRO-ACTION USAGE APPLICATIONS
| GREASE
TRAP |
Initial
Dosage |
Daily
Rate |
DRAIN
MAINTENANCE Twice/week or as needed |
|||
| |
Light |
Average |
Heavy |
Pipe
Size |
Usage |
|
| 0-100 gls (13 cf.) | ½
gl |
1-3
oz. |
3-5
oz. |
5-7
oz. |
2" |
3
oz. |
| 101-500 gls (67cf) | 1
gl |
4-6
oz. |
6-8
oz. |
8-10
oz |
4" |
6
oz. |
| 501-1000gls (134 cf.) | 2gls. |
6-10
oz. |
10-14
oz |
14-18
oz |
6" |
9
oz. |
| 1001-5000 gls | 4
gls |
14-18
oz. |
18-22
oz |
22-26
oz |
8" |
12
oz. |
| or 1.5 oz. Per inch of drain diameter. NOTE: Always start with lower floors first | ||||||
Waste Treatment
Plants/Sludge Disposal Trucks: Please call our technical service department
for additional product information. This product is available in bulk quantities.
Porta-Toilets: Add 1 pt. to tank.
Ponds, Lagoons: Use 3 gallons per million gallons of water flow/containment
for 12 days. After initial treatment, use 1 gallon per million gallons of water
daily.
HOW MICRO-ACTION WORKS FOR YOU
There usually aren't enough
natural bacteria in wastewater treatment systems to properly decompose the waste
before it leaves the system. Man-made wastewater treatment systems suffer from
high concentrations of organic waste, insufficient bacteria population and the
absence of the right kind of bacteria to decompose organic waste.
The results are noxious odors, sludge buildup, sewerage backups, wastes that
are discharged before they are completely decomposed, facilities that are overloaded
with organic waste, and a lot of expense for facility repair, disposal field
or bed replacement and pollution clean-up.
MICRO-ACTION works like nature, introducing
live, safe bacteria with known functions into your wastewater treatment facility
to improve waste decomposition. These bacteria require specific nutrients in
order to metabolize waste and reproduce. These food sources - carbon, nitrogen,
and phosphorus - are found in abundance in the waste-waters in municipal treatment
plants, septic tanks, extended aeration plants, package plants, lagoons and
ponds, fish hatcheries, industrial plants, and all other treatment facilities.
Our selected bacteria are 100% biodegradable, non-toxic, non-pathogenic, and
non-irritating. They are so safe, in fact, that the USDA approves them for use
in meat, egg and poultry plants. Suspended in a dormant state, they live for
more than 24 months inside our patented liquid chemical solution. Once in contact
with the nutrients present in your wastewater treatment facility, the bacteria
are reactivated. This population goes to work to liquefy grease and fats, to
reduce sludge buildup and line corrosion, to eliminate overloading and chemical
shocks, to increase dissolved oxygen in the final effluent, and to dramatically
reduce BOD, COD, and SS levels
MICRO-ACTION increases your wastewater treatment
capacity, making it an obvious alternative to expansion of your facilities and
a sensible was to extend the life of your facilities.
Only small amounts are required, and it's easy to apply from our one-gallon
containers. MICRO-ACTION is also available
in 5 and 55-gallon containers. No pre-mixing devices are required. Apply with
a chemical-metering pump, drip feed device or by hand, according to instructions.
PACKED: 4-1 gal, 5 gal, 35 gal, and 55 gal. Containers.
|
||||
|
||||
| Use of ENVIRO-OBT
in Grease Traps ENVIRO-OBT
can be used in eliminating
grease buildups in grease traps with excellent results. The method for
such use is as follows. |
||||
|
||||
| Directions For Use: Aboard Ships or Drilling Rigs ENVIRO-OBT
is most beneficial
to the Marine Sanitation Device when flushed down toilets. This allows
the bacteria to come to life and begin the breaking down process of waste
while it is still inside the pipes or holding tanks long before it enters
the system.
|
||||
|
213